将你提供的 C# 代码转换为 C++ 代码涉及到几个方面,包括连接 PLC 和设置 TCP 通信参数。在下面的示例中,我将展示如何用 C++ 实现与 Siemens S7 PLC 的连接,并设置相应的通信参数。
C++ 示例代码
这个示例使用了基础的 Socket API 来创建与 PLC 的连接。注意,这个实现是简化版本,可能不包括所有特性。
#include <iostream>
#include <cstring>
#include <arpa/inet.h> // For inet_addr, sockaddr_in, etc.
#include <unistd.h> // For close()
#include <fcntl.h> // For fcntl()
class SiemensS7Net {
public:
SiemensS7Net(const std::string& ipAddress, int port)
: ipAddress(ipAddress), port(port), socket_fd(-1) {}
bool connectToPLC(int connectTimeoutMs, int receiveTimeoutMs) {
socket_fd = socket(AF_INET, SOCK_STREAM, 0);
if (socket_fd == -1) {
std::cerr << "Failed to create socket." << std::endl;
return false;
}
struct sockaddr_in server_addr;
server_addr.sin_family = AF_INET;
server_addr.sin_port = htons(port);
server_addr.sin_addr.s_addr = inet_addr(ipAddress.c_str());
// Set the socket to non-blocking mode for timeout handling
fcntl(socket_fd, F_SETFL, O_NONBLOCK);
// Attempt to connect
int connectionResult = connect(socket_fd, (struct sockaddr*)&server_addr, sizeof(server_addr));
if (connectionResult == -1 && errno != EINPROGRESS) {
std::cerr << "Connection failed." << std::endl;
close(socket_fd);
return false;
}
// Check the result of the connection attempt
fd_set writefds;
FD_ZERO(&writefds);
FD_SET(socket_fd, &writefds);
struct timeval timeout;
timeout.tv_sec = connectTimeoutMs / 1000;
timeout.tv_usec = (connectTimeoutMs % 1000) * 1000;
if (select(socket_fd + 1, NULL, &writefds, NULL, &timeout) > 0) {
int errorCode;
socklen_t len = sizeof(errorCode);
if (getsockopt(socket_fd, SOL_SOCKET, SO_ERROR, &errorCode, &len) < 0 || errorCode != 0) {
std::cerr << "Error in connection." << std::endl;
close(socket_fd);
return false;
}
std::cout << "Connected to PLC." << std::endl;
// Set receive timeout here if needed...
return true;
} else {
std::cerr << "Connection timed out." << std::endl;
close(socket_fd);
return false;
}
}
void disconnect() {
if (socket_fd != -1) {
close(socket_fd);
socket_fd = -1;
}
}
private:
std::string ipAddress;
int port; // Default is Port 102 for S7 Communication
int socket_fd; // File descriptor for the TCP connection
};
int main() {
const int PORT = 102; // Standard port for S7 communication
SiemensS7Net plc("127.0.0.1", PORT);
if (plc.connectToPLC(5000 /* Connect Timeout */, 10000 /* Receive Timeout */)) {
// Successfully connected to the PLC.
plc.disconnect(); // Disconnect when done
} else {
std::cerr << "Failed to connect to PLC." << std::endl;
}
return 0;
}
注意事项
Socket API: 上面的代码使用了 POSIX Socket API 来处理 TCP/IP 通信。它在类 Unix 系统(如 Linux)中可正常工作。如果你在 Windows 平台上运行,需要使用 Winsock 库并进行一些修改。
超时处理: 我们通过将套接字设置为非阻塞模式来实现超时功能,并利用
select
函数来等待连接完成。根据需求,你也可以进一步实现接收数据超时。错误处理: 本示例包含了一些基本的错误处理,但对于实际应用而言,你可能需要更详细的检查和处理逻辑,以确保稳定性和可靠性。
如果你有具体需求或其他问题,请随时告诉我!
内容由零声教学AI助手提供,问题来源于学员提问